Reserve site: 700mm on the right, 200mm on the left, 1000mm on the front,,500mm on the back, 300mm on the top;
Voltage: RMS220:200-240VAC, 50/60Hz, 230VAC@15A; Build Unit 220:20-26VDC,24VDC@6A
Atmosphere Mode: Air Mode/Nitrogen Mode (RMS220 has a built-in nitrogen generator; compressed air is required).
Recommended nitrogen mode parameters: Pressure 0.1-0.8 MPa, flow rate ≥ 20 SLPM, purity ≥ 98%.
Recommended compressed air parameters: Pressure 0.5-0.8 MPa, flow rate ≥ 20 SLPM. Inlet air must be oil-, water-, and dust-free. We recommend installing a three-way fitting. Please follow the compressed air equipment manufacturer's instructions for installation.
⚠ Installation should be operated by personnel who have received professional training. Please wear protective measures for installation! Before installation, the equipment must be powered off!