This chapter will guide you on how to level the C220-P Cleaning Station.
19mm open-end wrench (to be prepared by yourself)
Leveling fixture (in your toolbox)

Insert the leveling fixture into the lower edge of the sheet metal of the Cleaning Station. Ensure that the lower edge of the fixture is fully inserted, and the higher edge can not be inserted.

Use a hand wrench to adjust the height of the four foot supports. First, use an open-end wrench to loosen the top screws downwards. Then, use the open-end wrench to loosen the bottom screws upwards to raise the feet.

After four foot supports are adjusted, push the Build Unit 220 into the Cleaning Station. If there are any abnormal noises or the Build Unit 220 cannot be pushed in, please readjust the height of the Cleaning Station.

Note: Ensure the guide surface of Build Unit 220 is flush with the guide wheels. If it cannot be flush or pushed in, please readjust the height of the Cleaning Station.
{.is-info}
After fully pushing the Build Unit 220 in, lock the casters.

If you push the C220-P away from its original position, it is recommended to level it again.